RDA / RDAT series
Full Bridge Phase Angle Controlled Thyristor Module Rectifier
Microprocessor Controlled System
Galvanically isolated / Primary & Secondary Earth Screened
110/127/190/200/220/230/240/380/ 400/415/480 VAC ±15% (1 Phase or 3 Phase)
50 Hz / 60Hz ±5%
≥ 0.8 Inductive (6 Pulse) ≥ 0.85 Inductive (12 Pulse) ≥ 0.95 Inductive (12 Pulse with active harmonic elimination)
≤ 30% (6 Pulse), ≤ 10% (12 Pulse), ≤ 5% (12 Pulse with active harmonic elimination)
Input: Thermic-Magnetic Over Current Protection, Over Voltage Protection, Phase Sequence Free Operation (3 Phase), Soft Start, MCB
Constant Current/ Constant Voltage
Depends on DC voltage and Current
12 / 24 / 48 / 110 / 125 / 220 / 264 / 360 / 450 / 900VDC
0-100% of Nominal Output Current
±0.5% (Lower values available upon request)
≤ 1% RMS AC of Output Voltage
2,4 lead acid battery 1,60 NiCd Battery (Depends on battery manufacturer recommendation)
2,23 lead acid battery 1,40 NiCd battery (Depends on battery manufacturer recommendation)
<50msec, <+/-5% (for 10% – 100%, 100% – 10% step load change)
Automatic or manual selectable. Please refer to user manual for details
0 – 99,9 hours adjustable by 1 minute accuracy
Total output current and battery current can be adjusted separately
“Low Battery, Mains Input Normal / Failure, Charger Failure, Overtemperature, Charger Overvoltage, Load MCB ON/ OFF, Battery MCB ON / OFF, Earth Fault”
LCD Display for Line Voltage / Frequency / Current (Standard in 1 Phase, Optional for 3 Phase), Battery Output Voltage / Current, Load Output Voltage, Charger Total Output Current
Float Mode, Boost Mode, Current Mode, Equalize Mode, Battery Ending, Low Battery, Battery Test Failure, Line Failure, Fan Failure, Over Voltage, Under Voltage, Over Temperature, Rectifier Failure, SCR Fuse Failure, Mains Available, Load MCB, Battery MCB
Float Charge Voltage, Boost Charge Voltage, Equalize Charge Voltage, Battery Charge Current, Rectifier Total Output Current, Low Battery Voltage Alarm, Earth Fault Leakage Current Alarm (only available in 4 line LCD), Battery Ending Voltage Alarm, Online Battery Test Parameters, Auto Boost Charge Parameters, Password
Events recorded and displayed on front panel and on PC via remote communication
On Warning Messages 2 Short ‘beep’ per 2 seconds
LCD Display for Line Voltage / Frequency / Current (Standard in 1 Phase, Optional for 3 Phase), Battery Output Voltage / Current, Load Output Voltage, Charger Total Output Current
Redundant Operation of Dual Chargers with Forced (Active) Load Sharing Option
Protection of Battery from Deep Discharge via Contactor. Available on request
Dropper Diodes for Float and Boost Voltage Regulations. Available on request
Input: Miniatur circuit breakers; Output: Miniatur circuit breakers / NH Fuse; Battery: Miniatur circuit breakers / NH Fuse
IEEE 587 4500 A, 110 Joules (standard) / 40kA Surge Arrestor (OPTIONAL)
FCC Part 15 Class B
EN 50091-1 (Security) / EN 50091-2 (EMC)
IP 20 / RAL 7035 (Standard), (Higher IP rating and different colors are available, please consult)
2000VAC input/chassis and output/chassis
100,000 hrs. (w/out battery group)
Mild Steel, Zinc-phosphate coated; 100 µm electrostatic paint; 1.5 mm thickness
Forced fans / Natural (optional)
Bottom / Top (optional)
OPTIONAL
OPTIONAL
-10 / +40 °C. Higher operating temperatures are available, please consult
0 – 90%. Higher relative humidity are available, please consult
Max. 1000 Mt. (Higher altitudes requires de-rating, please consult )
Max. 65 db